www.2n.czVersion2N ®Helios IP SafetyEmergency IP IntercomInstallation Manual2.1

Página 2

102N TELEKOMUNIKACE a.s., www.2n.cz®2. Description and InstallationHere is what you can find in this section:2.1 Before You Start2.2 Mechanical Insta

Página 3

112N TELEKOMUNIKACE a.s., www.2n.cz®2.1 Before You StartProduct Completeness CheckBefore you start please check the contents of your delivery:2N® He

Página 4 - 1. Product Overview

122N TELEKOMUNIKACE a.s., www.2n.cz®2.2 Mechanical InstallationMounting Type OverviewRefer below for a list of mounting types and necessary component

Página 5 - Advantages of Use

132N TELEKOMUNIKACE a.s., www.2n.cz®Flush mounting – hollow bricksWhat You Need:Brick flush mounting box, Part No. 9151001Hole: (132 × 223 × 83) mm F

Página 6 - Basic Units

142N TELEKOMUNIKACE a.s., www.2n.cz®Common Mounting PrinciplesCautionThe warranty does not apply to the product defects and failures arisen asa resu

Página 7 - Electric Locks

152N TELEKOMUNIKACE a.s., www.2n.cz®Flush Mounting – Classic BricksIf you use the brick flush mounting box, follow the instructions included in the b

Página 8 - Additional Modules

162N TELEKOMUNIKACE a.s., www.2n.cz®Flush Mounting – Thermally Insulated WallCut out the thermal insulation layer using the template (the same as for

Página 9 - 1.2 Terms and Symbols

172N TELEKOMUNIKACE a.s., www.2n.cz®Flush Mounting – Hollow BricksSuppose you intend to install your unit into a wall made of2N ®Helios I

Página 10 - 2.3 Electric Installation

182N TELEKOMUNIKACE a.s., www.2n.cz®Wall MountingWall (surface) mounting is used where flush mounting is inapplicable (in concrete andsteel structure

Página 11

192N TELEKOMUNIKACE a.s., www.2n.cz®1. 2. 3. 4. 5. 6. Select the 2N® Helios IP Safety position with respect to the supplycables. Wher

Página 12

The 2N TELEKOMUNIKACE a.s. is a Czech manufacturer and supplier of telecommunicationsequipment.The product family developed by 2N TELEKOMUNIKACE a.s.

Página 13 - What You Need:

202N TELEKOMUNIKACE a.s., www.2n.cz®How to Pull a RJ-45 Terminated Cable through a Bushing1. Unscrew the big bushing nut completely. 2. Remove the

Página 14 - Common Mounting Principles

212N TELEKOMUNIKACE a.s., www.2n.cz® 5. Pull the cable connector though the bushing body into the intercom and clip it intothe motherboard connector.

Página 15

222N TELEKOMUNIKACE a.s., www.2n.cz®

Página 16

232N TELEKOMUNIKACE a.s., www.2n.cz®2.3 Electric InstallationThis subsection describes how to connect into your Local Area2N ®Helios IP Safety Netw

Página 17 - Flush Mounting – Plasterboard

242N TELEKOMUNIKACE a.s., www.2n.cz®Connectors, PCB Version 555v3Figure: 2N ®Helios IP Safety Description of Connectors:X1 – LoudspeakerX4 – Camera m

Página 18 - Wall Mounting

252N TELEKOMUNIKACE a.s., www.2n.cz®X19 – 12 V / 1 A DC power inputLED1/2 – System status indicatorsLED3 – LAN connection activity indicatorLAN Conne

Página 19 - Use of Cable Bushings

262N TELEKOMUNIKACE a.s., www.2n.cz®1. 2. 3. 4. 5. 6. 1. 2. Factory Default Resetting (PCB version 555v2)Disconnect the device from the power

Página 20

272N TELEKOMUNIKACE a.s., www.2n.cz®1. 2. 3. 4. 5. 6. 7. 2.4 Extending Module Connection2N ®Helios IP Safety allows to connect following ext

Página 21

282N TELEKOMUNIKACE a.s., www.2n.cz®Module settings:Refer to the for details.2N Helios IP Configuration Manual®

Página 22

292N TELEKOMUNIKACE a.s., www.2n.cz®Connection:Security RelayThe (Part No. 9159010) is used for enhancing security between theSecurity R

Página 23

Content 1. Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41.1ComponentsandAssociatedProducts .....

Página 24

302N TELEKOMUNIKACE a.s., www.2n.cz®Installation:Install the onto a two-wire cable between the intercom2N Helios IP Security Relay®and the elect

Página 25 - Electric Lock Connection

312N TELEKOMUNIKACE a.s., www.2n.cz®Connection:

Página 26 - Mounting Completion

322N TELEKOMUNIKACE a.s., www.2n.cz®3. Function and UseIn this section we describe the basic and extending functions of the 2N® Helios IPp

Página 27 - Additional Switch

332N TELEKOMUNIKACE a.s., www.2n.cz®3.1 ConfigurationUse a PC equipped with any web browser to configure :2N® Helios IP Safety Launch your web brows

Página 28 - Module settings:

342N TELEKOMUNIKACE a.s., www.2n.cz®IP Address RetrievalTake the following steps to retrieve the IP address:2N® Helios IP Safety Connect (or, if con

Página 29 - Security Relay

352N TELEKOMUNIKACE a.s., www.2n.cz®The static IP address mode will be switched into the dynamic IP address mode and viceversa upon restart.CautionTh

Página 30 - Configuration:

362N TELEKOMUNIKACE a.s., www.2n.cz®3.2 MaintenanceCleaningIf used frequently, gets dirty. To clean it, use a piece of soft2N® Helios IP Safety clot

Página 31

372N TELEKOMUNIKACE a.s., www.2n.cz®4. Technical ParametersSignalling protocolSIPButtonsButton design: Industrial waterproof, stainless steel,

Página 32 - 3. Function and Use

382N TELEKOMUNIKACE a.s., www.2n.cz®Additional switchOptionalIncludes also tamper switchPassive switch: NO and NC contacts, up to 30 V / 1 A AC/DCAct

Página 33 - 3.1 Configuration

392N TELEKOMUNIKACE a.s., www.2n.cz®5. Supplementary InformationHere is what you can find in this section:5.1 Troubleshooting5.2 Directives, Laws and

Página 34 - IP Address Retrieval

42N TELEKOMUNIKACE a.s., www.2n.cz®1. Product OverviewHere is what you can find in this section:1.1 Components and Associated Products1.2 Terms and S

Página 35

402N TELEKOMUNIKACE a.s., www.2n.cz®5.1 Troubleshooting For the most frequently asked questions refer to .faq.2n.cz

Página 36 - 3.2 Maintenance

412N TELEKOMUNIKACE a.s., www.2n.cz®5.2 Directives, Laws and RegulationsEurope2N ®Helios IP Safety conforms to the following directives and regulati

Página 37 - 4. Technical Parameters

422N TELEKOMUNIKACE a.s., www.2n.cz®FCCNOTE: This equipment has been tested and found to comply with the limits for a ClassB digital device, pursu

Página 38 - Mechanical properties

432N TELEKOMUNIKACE a.s., www.2n.cz®5.3 General Instructions and CautionsPlease read this User Manual carefully before using the product. Follow all

Página 39 - 5. Supplementary Information

442N TELEKOMUNIKACE a.s., www.2n.cz®Electric Waste and Used Battery Pack HandlingDo not place used electric devices and battery packs into municipal

Página 40 - 5.1 Troubleshooting

452N TELEKOMUNIKACE a.s., www.2n.cz®2N TELEKOMUNIKACE a.s.Modřanská 621, 143 01 Prague 4, Czech RepublicPhone: +420 261 301 500, Fax: +420 261 301 59

Página 41 - Industry Canada

52N TELEKOMUNIKACE a.s., www.2n.cz®2N ®Helios IP Safety can also be provided with RFID card reader modules.2N ®Helios IP Safety is very easy to ins

Página 42

62N TELEKOMUNIKACE a.s., www.2n.cz®1.1 Components and Associated ProductsBasic Units9152101Part No. 1 button9152101WPart No. 1 button, 10 W loudspeak

Página 43

72N TELEKOMUNIKACE a.s., www.2n.cz®Mounting Accessories9152000Part No. Mounting frameorangeAluminum9151001Part No. Brick flush mounting boxStainless

Página 44

82N TELEKOMUNIKACE a.s., www.2n.cz®Power SupplyPart No. 91378100EPart No. 91378100USPoE injector91341481EPart No. Adapter 12 V / 2 AA stabilised powe

Página 45

92N TELEKOMUNIKACE a.s., www.2n.cz®1.2 Terms and SymbolsThe following symbols and pictograms are used in the manual:Safety abide by this information